DwellNet(TM) DN290 -- Controller for X-10(R) CP290 To use interactively: Select COM port (connected to CP290), house code and unit code of X-10 unit to control, and click the On, Off, or Dim button corresponding to the desired action. To use with Microsoft(R) Windows 98 task scheduler: Run interactively (as described above), but check "Copy Cmd. Line To Clipboard" first. After clicking an On, Off, or Dim button, open the Scheduled Tasks window (Start, Programs, Accessories, System Tools), and use Ctrl+V to paste the command line corresponding to the On/Off/Dim action into the Properties page of a new task. Command line parameters: /cX = select COM port X (1 to 4) /hX = select house code X (A to P) /uX = select X-10 unit X (1 to 16) /on = turn on selected unit /onX = dim selected unit to X (1 to 14) /off = turn off selected unit If /on or /off are specified, DN290 quits after the command line is executed. Command line parameters default to the values specified when DN290 was last run interactively. ----------------------------------------------------------------------------- This software is provided "as is" -- no warranty is expressed or implied. "DwellNet" is a trademark of DwellNet Technologies. "Microsoft" and "Windows" are trademarks of Microsoft Corporation.