These ratings are average values obtained in accordance with accepted test methods. Superlon products perform best within the operating temperature range. Out of this temperature range, Superlon materials become increasing harden & brittle. However, this hardening characteristic does not affect thermal insulation or water vapour permeability abilities. The fire rating method of tests conducted under controlled laboratory conditions is a measure of a material to contain flame or heat , & is not intended to reflect hazards presented by this or other material under actual fire conditions.
 
Properties Ratings Test Methods
Cellular Structure    
Density (Kg/m3)    
Thermal Conductivity
@ Mean Temp. 20 oC
0.28 Btu.in/hr.ft2.F
0.038 W/moC
(0.0328 Kcal/mhoC)
BS 874 : Part 2
Temperature Limits oC - 40 oC To + 105 oC -
Thermal Stability (5% Shrinkage)
7 days @ 200 oF
7 days @ 220 oF

4.5
5.5

ASTM C534
ASTM C534
Fire Resistance Class O
Class 1
Seft Extinguishing
V- 0, 5 VA
BS 476 Part 6
BS 476 Part 7
ASTM D - 635
UL94/JIS K6911
Toxicity 3095 NES 713
Water Absorption (% W/W) 3.85 ASTM C 272 / 1056
Water Vapor Permeability
Perm-In. Max g/Pa.s.m2
0.29 ug.m/N.h
8.17 x 10 -14

ASTM D 1171 / JIS K6301
Mildew Resistance No fungal growth -
Weather & UIV Resistance Good -
Ozone Resistance Excellent ASTM D 1171 / 1056
Chemical Resistance Good -
Odour Negligible -
Flexibility Excellent -
Product Process W / O CFC, Asbestos, Chlorine, & Fiber -
Coating, with release paper Adhesive, tested OK Under temperature 80 C & 500 hrs -
1