Acid-Base Titrations (Second Derivative)
The following data values are based on the sample data displayed on the Acid-Base Titrations (Titration Curve) page. The data is used to graph Δ(ΔpH/ΔV)/ΔV vs Volume which represents the second derivative of the pH data (Δ(ΔpH/ΔV)/ΔV).
Vave (mL) ΔpH/ΔV ΔV (mL) Δ(ΔpH) Vave (mL) Δ(ΔpH/ΔV)/ΔV Vave (mL) ΔpH/ΔV ΔV (mL) Δ(ΔpH) Vave (mL) Δ(ΔpH/ΔV)/ΔV 1.50 0 01.00 0 0 0 15.50 4.90 1.00 0.15 15.00 0.152.50 3.24 1.00 00 0 16.25 6.93 0.75 2.03 15.88 2.713.50 3.39 1.00 0.153.00 0.15 16.75 10.80 0.50 3.87 16.50 7.734.50 3.54 1.00 0.154.00 0.15 17.25 11.20 0.50 0.40 17.00 0.805.50 3.63 1.00 0.095.00 0.09 17.75 11.90 0.50 0.70 17.50 1.406.50 3.78 1.00 0.156.00 0.15 18.25 13.20 0.50 1.30 18.00 2.607.50 3.85 1.00 0.077.00 0.07 18.60 20.86 0.35 7.66 18.43 21.888.50 3.98 1.00 0.138.00 0.13 18.80 38.00 0.20 17.14 18.70 85.719.50 4.11 1.00 0.139.00 0.13 19.00 40.75 0.20 2.75 18.90 13.7510.25 5.60 0.75 1.499.88 1.99 19.20 49.75 0.20 9.00 19.10 45.0010.75 8.52 0.50 2.9210.50 5.84 19.90 15.00 0.70 -34.75 19.55 -49.6411.25 8.62 0.50 0.1011.00 0.20 20.75 12.82 0.85 - 2.18 20.33 - 2.5611.75 8.78 0.50 0.1611.50 0.32 21.25 23.60 0.50 10.78 21.00 21.5512.50 5.96 0.75 - 2.8212.13 - 3.76 22.00 16.27 0.75 - 7.33 21.63 - 9.7813.50 4.60 1.00 - 1.3613.00 - 1.36 23.00 12.30 1.00 - 3.97 22.50 - 3.9714.50 4.75 1.00 0.1514.00 0.150 0 0 0 0 0The equivalence point corresponds to the volume at which the second derivative is zero. Note the equivalence point found on the Acid-Base Titrations (Titration Curve) page is in close agreement with the 19.60 mL.
This is not the only method to determine the equivalence point, so be sure to check out Acid-Base Titrations (Titration Curve), Acid-Base Titrations (First Derivative), and Acid-Base Titrations (Gran Plot).
©2004, Flinn Scientific, Inc. All Rights Reserved. Reproduced for one-time use with permission from Flinn Scientific, Inc., Batavia, IL, USA. No part of this material may be reproduced or transmitted in any form or by any means, electronic or mechanical, including, but not limited to photocopy, recording, or any information storage and retrieval system, without permission in writing from Flinn Scientific, Inc.; and
That the Licensee agrees to indemnify and hold Flinn Scientific, Inc. harmless from any and all liability, loss, damages, costs of expense which Flinn Scientific, Inc. may hereafter incur, suffer or be required to pay by reason of such publication by the Licensee; and
To compensate Flinn Scientific, Inc. $0.00 for the permission to reproduce this material.